10kV oil-immersed three-phase double-winding voltage regulation distribution transformer energy efficiency class(30kVA-2500kVA)
Rated Capacity: 315–2,500 kVA
High Voltage: 6 / 6.3 / 10 / 10.5 kV
Low Voltage: 0.4 kV
Transformer Type: Three-phase oil-immersed distribution transformer
Vector Group: Dyn11 / Yzn11 / Yyn0
Voltage Regulation: Off-circuit, tapping range ±2×2.5% / ±5%
Product Introduction
Product Overview
Yawei Electric's 10 kV oil-immersed three-phase double-winding distribution transformer is designed for medium-voltage distribution systems. The parameter table lists rated capacities from 315 to 2,500 kVA, high-voltage options of 6 / 6.3 / 10 / 10.5 kV, and a 0.4 kV low-voltage side.
Available table configurations include Dyn11 / Yzn11 / Yyn0 vector groups and off-circuit tapping ranges of ±2×2.5% / ±5%. Final capacity, voltage, winding, cooling arrangement and applicable standard are confirmed against the project specification and technical agreement.
Technical Specifications
10 kV oil-immersed three-phase double-winding distribution transformer (315–2,500 kVA).
| Rated capacity (kVA) | HV (kV) | Tapping range (%) | LV (kV) | Vector group | No load current (%) | Impedance voltage (%) | No load losses (kW) | On load losses - Dyn11/Yzn11 (kW) | On load losses - Yyn0 (kW) |
|---|---|---|---|---|---|---|---|---|---|
| 315 | 6 / 6.3 / 10 / 10.5 | ±2×2.5 / ±5 | 0.4 | Dyn11 / Yzn11 / Yyn0 | 0.72 | 4.0 | 270 | 2760 | 2630 |
| 400 | 0.64 | 330 | 3250 | 3095 | |||||
| 500 | 0.64 | 385 | 3900 | 3710 | |||||
| 630 | 0.48 | 4.5 | 460 | 4460 | |||||
| 800 | 0.48 | 560 | 5400 | ||||||
| 1000 | 0.48 | 665 | 7415 | ||||||
| 1250 | 0.4 | 780 | 8640 | ||||||
| 1600 | 0.4 | 940 | 10440 | ||||||
| 2000 | 0.32 | 5.0 | 1085 | 13180 | |||||
| 2500 | 0.32 | 1280 | 15270 | ||||||
Application


Customization Service

Certifications

Packing and Delivery
Testing and Quality Assurance
Each transformer undergoes factory testing before delivery according to the agreed specification, including:
- Routine tests (ratio, resistance, losses)
- Type tests (temperature rise, impulse test)
- Special tests (upon request)
Applicable standards and required tests are confirmed according to the project specification and final technical agreement.
Installation and Maintenance
The transformer is designed for easy installation and low maintenance:
- Suitable for outdoor or indoor installation
- Minimal maintenance due to sealed oil system
- Periodic inspection recommended for long-term performance
Tell us the required capacity, primary and secondary voltages, phase, frequency, installation environment, applicable standard, and delivery destination. Our sales and engineering teams will review your requirements and respond within one business day.