10kV oil-immersed three-phase double-winding voltage regulation distribution transformer energy efficiency class(30kVA-2500kVA)


Rated Capacity: 315–2,500 kVA
High Voltage: 6 / 6.3 / 10 / 10.5 kV
Low Voltage: 0.4 kV
Transformer Type: Three-phase oil-immersed distribution transformer
Vector Group: Dyn11 / Yzn11 / Yyn0
Voltage Regulation: Off-circuit, tapping range ±2×2.5% / ±5%

Product Introduction


Product Overview

Yawei Electric's 10 kV oil-immersed three-phase double-winding distribution transformer is designed for medium-voltage distribution systems. The parameter table lists rated capacities from 315 to 2,500 kVA, high-voltage options of 6 / 6.3 / 10 / 10.5 kV, and a 0.4 kV low-voltage side.

Available table configurations include Dyn11 / Yzn11 / Yyn0 vector groups and off-circuit tapping ranges of ±2×2.5% / ±5%. Final capacity, voltage, winding, cooling arrangement and applicable standard are confirmed against the project specification and technical agreement.

Technical Specifications

10 kV oil-immersed three-phase double-winding distribution transformer (315–2,500 kVA).

Rated capacity (kVA) HV (kV) Tapping range (%) LV (kV) Vector group No load current (%) Impedance voltage (%) No load losses (kW) On load losses - Dyn11/Yzn11 (kW) On load losses - Yyn0 (kW)
315 6 / 6.3 / 10 / 10.5 ±2×2.5 / ±5 0.4 Dyn11 / Yzn11 / Yyn0 0.72 4.0 270 2760 2630
400 0.64 330 3250 3095
500 0.64 385 3900 3710
630 0.48 4.5 460 4460
800 0.48 560 5400
1000 0.48 665 7415
1250 0.4 780 8640
1600 0.4 940 10440
2000 0.32 5.0 1085 13180
2500 0.32 1280 15270

Application

Customization Service

Certifications

 Packing and Delivery

Testing and Quality Assurance

Each transformer undergoes factory testing before delivery according to the agreed specification, including:

  • Routine tests (ratio, resistance, losses)
  • Type tests (temperature rise, impulse test)
  • Special tests (upon request)

Applicable standards and required tests are confirmed according to the project specification and final technical agreement.

Installation and Maintenance

The transformer is designed for easy installation and low maintenance:

  • Suitable for outdoor or indoor installation
  • Minimal maintenance due to sealed oil system
  • Periodic inspection recommended for long-term performance