Products

Products

35kV oil-immersed three-phase double-winding off-circuit voltage regulating power transformer


Rated Capacity: 3,150–25,000 kVA
High Voltage: 35 / 36 / 37 / 38.5 kV
Low Voltage: 6 / 6.3 / 10 / 10.5 / 11 kV
Transformer Type: Three-phase oil-immersed double-winding power transformer
Vector Group: Dyn11 / Yd11
Voltage Regulation: Off-circuit, table tapping range +4×2.5%

Product Introduction


Product Overview

Yawei Electric's 35 kV oil-immersed three-phase double-winding off-circuit voltage regulating power transformer is designed for medium-voltage power systems. The parameter table lists rated capacities from 3,150 to 25,000 kVA, high-voltage options of 35 / 36 / 37 / 38.5 kV, and low-voltage options of 6 / 6.3 / 10 / 10.5 / 11 kV.

Available table configurations include Dyn11 / Yd11 vector groups and off-circuit voltage regulation with a table tapping range of +4×2.5%. Final capacity, voltage, winding, cooling arrangement and applicable standard are confirmed against the project specification and technical agreement.

Technical Specifications

35 kV oil-immersed three-phase double-winding off-circuit voltage regulating power transformer (3,150–25,000 kVA).

Rated capacity (kVA) HV (kV) Tapping range (%) LV (kV) Vector group No load current (%) Impedance voltage (%) No load losses (kW) On load losses - B (100°C) (kW) On load losses - F (120°C) (kW) On load losses - H (145°C) (kW)
3150 35 / 36 / 37 / 38.5 +4×2.5 6 / 6.3 / 10 / 10.5 / 11 Dyn11 / Yd11 0.6 7.0 5.67 24 25.4 27.2
4000 0.6 8.0 6.64 28.7 30.4 32.6
5000 0.5 7.85 34 36.1 38.6
6300 0.5 9.27 39.4 41.8 44.7
8000 0.45 9.0 10.6 44.8 47.5 50.8
10000 0.45 12.1 53.9 57.1 61.2
12500 0.35 14.7 62.7 66.5 71.1
16000 0.35 18.1 73.8 78.2 83.7
20000 0.3 10.0 21.4 83 88 94.2
25000 0.3 25.2 98.2 104 111

Application

Customization Service

Certifications

 Packing and Delivery

Testing and Quality Assurance

Each transformer undergoes factory testing before delivery according to the agreed specification, including:

  • Routine tests (ratio, resistance, losses)
  • Type tests (temperature rise, impulse test)
  • Special tests (upon request)

Applicable standards and required tests are confirmed according to the project specification and final technical agreement.

Installation and Maintenance

The transformer is designed for easy installation and low maintenance:

  • Suitable for outdoor or indoor installation
  • Minimal maintenance due to sealed oil system
  • Periodic inspection recommended for long-term performance

Tell us the required capacity, primary and secondary voltages, phase, frequency, installation environment, applicable standard, and delivery destination. Our sales and engineering teams will review your requirements and respond within one business day.

%{tishi_zhanwei}%