Vehicle-Mounted Mobile Transformer


A vehicle-mounted mobile transformer provides a flexible substation solution designed for temporary, emergency, and other specialized power requirements.

Product Introduction


Product Overview

Temporary power supply
Where electricity demand grows faster than planned grid construction, the mobile unit can serve as a temporary substation to ease supply constraints. It can also provide interim or rental service while a permanent substation project is delayed by budget, scheduling, or other project conditions.
Expansion and refurbishment of existing substations
During equipment maintenance, capacity expansion, or substation renovation, the mobile transformer can provide short-term replacement capacity when continuity of supply is essential.
Emergency and disaster response
When severe weather, natural disasters, or other external events interrupt service, a mobile substation can replace all or part of a conventional installation, restore electricity quickly, and reduce outage duration.

Technical Specifications

Vehicle-Mounted Mobile Transformer

SNNameModel
Primary electrical equipment
1Power transformerSF5000/110; 115 ±2 × 2.5% / 36.5 kV; Ud = 10.5%; YN,d11; ONAF; filled with 45# transformer oil
2Neutral point complete set of grounding equipmentGW13-72.5, 630 A; discharge gap 120 ±5 mm; MCT 100–300/1 A, 10P20, 30 VA; arrester YH1.5W5-72/186
3110 kV HGIS combined switchgear126 kV, 2000 A, 40 kA assembly including circuit breaker, current transformer, disconnecting switch, earthing switch, bushings, and related components
4110kV voltage transformerTYD-110/√3-0.01H; 110/√3 / 0.1/√3 / 0.1/√3 / 0.1 kV; classes 0.2/0.5/3P; 20 VA / 30 VA / 50 VA
5110 kV zinc-oxide surge arresterYH10WZ-108/281; Ur = 88 kV; In = 10 kA; supplied with discharge counter
635kV incoming and outgoing line cabinet40.5 kV circuit-breaker cabinet, rated 1250 A / 31.5 kA, with top-to-bottom incoming arrangement
735kV busbar equipment cabinetPT cabinet with 0.5 A fuse, bottom-connected surge arrester, and primary harmonic-elimination device
835kV substation transformer cabinet30 kVA station-service transformer with 1 A fuse; final configuration subject to project design
Secondary electrical equipment
1Power transformer protection, metering, and control panelIntegrated main and backup protection units; high- and low-voltage measurement/control units; transformer body protection; common measurement and control unit
2Monitoring and remote control cabinetDual main/standby remote-control units; dispatch conversion device; two monitoring hosts with integrated automation and interlocking; network switch; time-synchronization device; electrical data acquisition unit
3AC/DC power supply panelDC supply: 3 × 10 A / 220 V; UPS supply: 2 kVA
4Battery screen50 Ah, DC 220 V
5Multifunction power meterGrade 0.5
6Multifunction energy meter0.2S
Auxiliary equipment
1Semi-trailerThree-line, six-axle suspension with load capacity above 75 t, including gooseneck, suspension, and support systems; suitable for Class IV road access requirements
2CabinEnclosed cabin for secondary panels and switchgear, complete with fire alarm, air conditioning, lighting, and electric heating
3Transport-condition online monitoringAcceleration sensor, GPS positioning unit, and forward/rearward driving cameras
4Automatic SF6 gas filling and recovery unitPressure-condensing design with hermetic SF6 compressor; filling rate above 40 kg/h (6–10 m³/h); recovery rate 40 kg/h (8 m³/h)
5Vehicle access handrails and boarding ladderSupplier to ensure safe operating access; trolley ladder designed with a self-retracting mechanism.

 

Application

Product Features  

✔ High Efficiency and Energy Saving
✔ Superior Thermal Performance
✔ Strong Overload Capability
✔ Flexible Customization Options
✔ Durable and Weather-Resistant Design
✔ Low Noise Operation

 

Customization Service

Certifications

Packing and Delivery

Testing and Quality Assurance

Routine Electrical Tests: insulation resistance, winding resistance, voltage ratio, load loss, no-load loss
High Voltage & Dielectric Tests: lightning impulse, short-circuit withstand, dielectric strength
Temperature Rise Tests: ensures stability under maximum load and continuous operation
Noise and Vibration Tests: industrial noise reduction and minimal vibration for sensitive environments
Oil Quality Analysis: dielectric strength, moisture content, and chemical stability

Installation and Maintenance

The transformer is designed for easy installation and low maintenance:

  • Suitable for outdoor or indoor installation
  • Minimal maintenance due to sealed oil system
  • Periodic inspection recommended for long-term performance

Tell us the required capacity, primary and secondary voltages, phase, frequency, installation environment, applicable standard, and delivery destination. Our sales and engineering teams will review your requirements and respond within one business day.